FAVEKER-Gres Aragón Tests Ventilated Facade Fire Performance
In 2019, FAVEKER-Gres Aragón created a ventilated facade system featuring tiles and conducted a voluntary test using an international full-scale fire propagation method aligned with the NFPA 285 standard. This assessment measures how well assemblies perform against both vertical and lateral fire spread, examining components such as extruded tiles, the mechanical anchorage system, metal substructure, rockwool insulation, and air cavity compartmentalization. The certification was granted by Thomas Bell-Wright International Consultants (Dubai), a body accredited under ISO/IEC 17065. As the technical standards for building envelopes progress, fire performance has emerged as a crucial factor in the design of ventilated facades, emphasizing the collective response of the entire envelope to external fire threats rather than just the reaction of individual materials.
Key facts
- FAVEKER-Gres Aragón developed a tiled ventilated facade system.
- The system was voluntarily tested in 2019.
- The test method is based on the NFPA 285 standard.
- It evaluates vertical and lateral fire propagation.
- Components tested include extruded tiles, anchorage, substructure, insulation, and cavity compartmentalization.
- Certificate issued by Thomas Bell-Wright International Consultants (Dubai).
- Thomas Bell-Wright is ISO/IEC 17065 accredited.
- Fire performance is now a key criterion in ventilated facade design.
Entities
Institutions
- FAVEKER-Gres Aragón
- Thomas Bell-Wright International Consultants
- ISO/IEC 17065
Locations
- Dubai
- United Arab Emirates